What the public record says
Post Deep Dynamic Compaction (DDC) verification testing in form of four (4) geotechnical soil borings, each advanced to a maximum depth of 15 feet below existing ground surface. Standard Penetration Testing (SPT) will be performed continuously at 2-foot intervals from the ground surface to the termination depth. Backfill verification borings with a low-strength cement-bentonite grout placed by tremie from the bottom of the boring to the ground surface. Grout shall be sufficiently fluid to permit pumping but shall develop sufficient strength to prevent subsequent settlement.
Recorded milestones
- Permit issued
Milestones apply to the recorded permits. They do not confirm that an entire development is complete or a business is open. No opening date is inferred.
Sources & confidence
Category labels may be inferred from official fields and scope descriptions. Related permits are grouped only where an explicit source project identifier is available. We do not combine unrelated permits merely because they share an address.
View original city source ↗Retrieved 11/9/2026, 7:40:20 PM. Latest successful source retrieval.